výkon Input 230V

Load 230V max 16A

senzor
NTC 10kOm

Termoregulator 16H

ТР-16Н has a built-v clock pre time scheduling a a weekly timer that allows you do schedule different temperatures pre each day week. na top that it is possible do set up do 8 teplota points per day.
This device does not need re-setting temperatures after turning off test. All settings are protected v low-výkon memory, except pre set main teplota (see main teplota setting).
unit has a BAT 2032-3V battery - which allows settings do be retained before a sudden výkon cut. regulator has a ovládanie a fuse against short-circuit, a emergency signalling against too low alebo too high teplota. pre convenient ovládanie there are such functions as: hysteresis teplota, emergency alarm, pause before switching na, three modes operation (vykurovanie, cooling, interval), reset.

 

Technical characteristics

Operating voltage ….…........................................................................................................................ 230V +/-20%

Full-load amperage …..........................................................................................................................16A

výkon consumption ….........................................................................................................................1W

senzor wire length as a set ….............................................................................................................2m (can be extended do 30m)

senzor teploty application type …...........................................................................................thermoresistor NTC 10kOm

Instrument operation mode …...........................................................................................................vykurovanie, cooling, interval

Hysteresis adjustable …......................................................................................................................1-70 °C

Response delay relé …...............................................................................................................….0-250sek

Operating ambient teplota .......................................................................................................0-40 °C

Lower bound teplota measurement …................................................................................-50 °C

Upper bound teplota measurement …...............................................................................+125 °C

teplota accuracy…......................................................................................................................0,1 °C

Number teplota points per day ..........................................................................................do 8

ElTotal number teplota points ….........................................................................................56

Planning clock reserve …....................................................................................................................Min. 1 year

Battery…..............................................................................................................................................BAT 2032-3V

Meaning buttons

B- short pressing a button - switching settings v menu alebo confirming set meaning. Pressing a holding pre 2 sec.

🠋- exit do previous menu, exit alebo enter into settings.
🠉- short press na this button - decrease selected meaning. - short press this button - increase selected meaning. If within 5 sec. If no button has been pressed within 5 sec, regulátor will automatically exit do main menu.

 

Setting lower teplota alarm .....

Briefly press button B , do select meaning Ɐ v settings menu. display will show teplota setting. Then use 🠋 a 🠉 buttons do select correct teplota pre alarm sounder a press button B
regulátor will save changes (there will be a short beep), a switch do setting selection menu. After that you can enter do next settings by short pressing button B, alebo you can leave settings menu by holding down button B pre 2 seconds. If no button is pressed within 5 seconds, regulátor will automatically exit settings menu.

 

Setting operating mode regulátor

Briefly press button B do set HEAt value v setting menu. Then use 🠋 a 🠉 buttons do select desired mode a press button, regulátor will save changes (there will be a short beep), a enter settings menu. Then s a short press B you can select next setting pre change alebo exit setting menu by holding down B pre 2 sec. If no button is pressed within 5 seconds, regulátor automatically exits settings menu.
Note: next time you enter operating mode selection menu, display will show current mode.

 

tool has three modes:

1) HEAt- (vykurovanie) - example operation: set teplota 30°C, hysteresis 5°C. v this case contacts regulátor 1 a 2 will close if teplota goes down do 25°C a close if it reaches 30°C.

2) COOL- (cooling) - example operation: set teplota 30°C, hysteresis 5°C. v this case contacts regulátor 1 a 2 close when teplota rises do 35°C a close when it drops do 30°C.

3) -[ ]-(interval) - example operation: set teplota 30°C, hysteresis 5°C. v this case contacts 1 a 2 will always be closed v teplota range from 25°C do 35°C.

 

Resetting settings do factory default

s a short press B button, select v settings menu meaning dEL. Then s 🠋 a 🠉 buttons select YES alebo NO a press button B do confirm. If YES is selected, regulátor resets settings (there will be a long beep), a goes na do settings menu. Then you can select next setting by briefly pressing button B, alebo exit setting menu.

 

Disconnection battery

This function allows you do disconnect battery from clock if it will not be used pre a long time, thus prolonging its life. do perform this function, disconnect regulátor from 220V mains, then press a hold button B a apply výkon do device again, while holding down button B . Then release B button a display will show "StOP". next time regulator is connected do mains display will show "StOP", this means that time is not set a battery is disconnected.

Note: manufacturer sends regulators s battery disconnected.

 

Setting time s a disconnected battery

display shows "StOP", do set time na regulátor press any key. It will be necessary do set current time. Short pressing buttons 🠋 a 🠉 decreases alebo increases significance. Button B change do day week d : ... . pri next press B, exit setting. After setting time there will be an automatic connection do battery. next time you disconnect device from mains, you will not need do set time again, because clock will run na battery.

 

Correcting time

Press a hold pre 2 sec. B, regulátor will enter time adjustment mode. Short pressing buttons 🠋 a 🠉 will increase alebo decrease significance. Button B switching do day week d : .... next time B button is pressed, regulátor will exit setting.

 

Switching off regulátor s ovládanie button

 

 do switch off appliance, press pre 5 seconds 🠋 button, a short beep will sound a display will show OFF. do switch do normal mode, press 🠋 button pre 2 seconds.

Note: when using this function, Regulácia teploty a measurement does not take place, ovládanie contacts 1 a 2 are always open.

 

Locking ovládanie buttons

do enable button locking, hold button 🠉 pre 5 sec. pre switching do normal mode, hold down 🠉 button pre 5 sec.
Note: if this function is enabled, bLOC will be displayed when any button is pressed.

 

 

Setting teplota over time

  By briefly pressing 🠋 alebo 🠉 button, you can set teplota teplota point running pri time. Then press button B do confirm, regulátor will save setting. This teplota will be stored.
only do move na do next teplota point. v future, teplota point will operate according do set teplota meanings v clock settings.
Note: if PoFF mode is selected (clock disconnected), set teplota changes a is stored v program.

 

Quick teplota change v clock settings

s a short press 🠋 alebo 🠉, change teplota. Then press a hold button B pre 2 seconds do confirm, regulátor will save changes (there will be a short beep). This teplota will be changed a saved v clock settings currently active teplota point.
Note: This function allows you do quickly change teplota current teplota point.

 

Setting teplota by timer P..

s a short press na B, find meaning P.... v settings menu Then s 🠋 a 🠉 buttons select one meanings a confirm s B, regulátor will save (there will be a short beep), a go na do teplota point settings respective mode.

 

Modes variants:
PoFF - timer(timer) disconnected, operates all time s same teplota.
P1-1 - timer na, up do 8 teplota points can be set pre each day week (weekly mode).
P1-5 - timer na, up do 8 teplota points can be set na first day week, a are set from 1st do 5th day (day mode). na 6th a 7th day week 8 points are set separately.
P1-6 - timer na, na first day week you set up do 8 points, a they are substituted from day 1 do day 6 (weekly mode). na 7th day up do 8 points are set separately.
P1-7 - timer na, up do 8 points are set na first day week a substituted na days 1 do 7 (weekly mode). Then 🠋alebo🠉 set teplota point na desired day/days (Р1-5, Р1-6, Р1-7) week, pre change a press button B.
If teplota point has not been activated, there will be dashes instead time a teplota settings.

Note: by pressing a holding button pre 2 sec selected teplota point can be deactivated.

 

do activate selected point, press 🠋 alebo 🠉 . Set time (by pressing 🠋 a 🠉 ) from which selected teplota point will start operating. Press B, then set teplota point ( 🠋 a 🠉 ). next time you press B, regulátor will go na do select teplota point.
Note: if teplota point was activated pri time change, regulátor will display set time a teplota.
Then s a short press 🠋 alebo 🠉 you can select next teplota point pre change alebo exit timer setting by holding down B pre 2s. If nothing is done within 15 seconds, regulátor will automatically exit settings.

 

Setting hysteresis G..

Briefly press B, then find meaning G ... display will show hysteresis teplota. Then s 🠋 a 🠉 select desired teplota a confirm s B

Battery replacement.

If operation is not correct, replace BAT 2032-3V battery.