top of page

  From July 2022, we are equipping all control panels for single-phase and three-phase boilers (Galan and GAZDA) with electricity meters.
In addition to kilowatts consumed, it also displays amperes and volts for each phase, cosφ, etc. All wiring diagrams apply to both Galan and Gazda boilers. The only difference is that single-phase Gazda boilers do not have an earthing terminal, as these boilers are covered with dielectric polymer material and do not need earthing.

Single-phase wiring diagram for Galan boilers with electric meter
Single-phase wiring diagram for Galan boilers with electric meter
This is a simple wiring diagram for single-phase boilers up to 4 kW.
For single-phase boilers of 5 and 6 or 8 kW. It differs from the previous scheme with another (more powerful, up to 63A) magnetic contactor and another main switch (from 25A to 40A).
This is a simple wiring diagram for single-phase GAZDA boilers up to 4 kW
Якорь 1
For single-phase GAZDA boilers of 6 or 8 kW
This is a simple wiring diagram for single-phase GAZDA boilers up to 4 kW.
simple wiring diagram for single-phase GAZDA boilers up to 4 kW
For single-phase GAZDA boilers of 6 or 8 kW. It differs from the previous scheme with another (more powerful, up to 63A) magnetic contactor and another main switch (from 25A to 40A).
simple wiring diagram for single-phase GAZDA boilers up to 8 kW

It is the scheme shows how to connect follow-up a temperature regulator air to the existing control unit with a temperature regulator on water. For an example it is represented Computherm q7, but it is possible to use any air temperature regulator.

Wiring diagram of GAZDA boiler GM series
Wiring diagram of GAZDA boiler GM series (GM102/104/106)

1-External control device (room thermostat, Wi-Fi relay with potential-free contacts, etc.).
2-Circulation pump
3-Power supply lines

1-External control device (room thermostat, Wi-Fi relay with potential-free contacts, etc.).
2-Circulation pump

3-Control box (overcurrent circuit breaker, meter indicating
current, voltage and current power consumption)

These two wiring diagrams of GAZDA single-phase monoblock boilers GM series. The difference in the two circuits is that the second circuit is supplemented with an electricity meter (in addition to the readings of the energy consumed, there is a possibility of displaying the current and voltage)

Circuit for three-phase boilers with electricity meter

Wiring diagram for three-phase boilers such as Geyser 4.5, Geyser 6, Geyser 9, Geyser 12, Geyser 15, Geyser 18 and Volcano 25

Circuit for three-phase boilers with electricity meter

Exactly the same wiring diagram as shown above, but with the option of connecting an air thermostat

Connection diagram of electrode boiler with control box with WIFI thermoregulator Konlen

Wiring diagram with WI-FI thermostat. In this example the regulator model KL-WF96D (KONLEN)

We are pleased to introduce the updated Konlen thermostat, produced since January 2024, designed to provide even more precise control over your heating.

wiring diagram of Galan single-phase electric boiler with Konlen thermo regulator

This diagram represents the connection of the Wi-Fi thermostat Konlen for a single-phase Galan electrode boiler with a power of up to 3 kW. The thermostat controls the boiler's switching on and off based on the temperature sensor's readings of the heat carrier.

The Konlen thermostat controls the power supply to the boiler by sending a current to the coil of the magnetic contactor through a physical connection. The operating parameters of the thermostat can be remotely configured via Wi-Fi using a mobile application.

The contactor, shown on the right side of the diagram, is designed for a maximum current of up to 20 A, which corresponds to the load of single-phase Galan boilers with a power of up to 3 kW. The regulation and control of the thermostat are carried out through a mobile application, allowing the user to set the required temperature and monitor the system's operation.

 

The boiler's connection to the thermostat is carried out according to the electrical diagram, ensuring the correct functioning of the heating system.

This diagram represents the connection of the Wi-Fi thermostat Konlen for a single-phase Galan electrode boiler with a power of up to 6 kW. The thermostat controls the boiler's operation by activating or deactivating based on the readings from the temperature sensor of the heat carrier.

The Konlen thermostat regulates the boiler's power supply by sending a current to the coil of the magnetic contactor through a physical connection. The operating parameters of the thermostat can be adjusted remotely via Wi-Fi using a mobile application.

The contactor, shown on the right side of the diagram, is designed for a maximum current of up to 40 A, accommodating the load of single-phase Galan boilers with a power of up to 6 kW.

The regulation and control of the thermostat are conducted through a mobile application, which allows the user to set the desired temperature and monitor the system's operation.

The boiler is connected to the thermostat following the electrical diagram, ensuring the correct functioning of the heating system.

This diagram outlines the setup for connecting the Wi-Fi thermostat Konlen to a three-phase Galan electrode boiler with a capacity of up to 25 kW. The thermostat manages the boiler's functionality, toggling it on or off based on the heat carrier's temperature sensor readings.

The Konlen thermostat controls the boiler's power supply by directing a current to the coil of a 63 A magnetic contactor via a physical connection. Users can remotely fine-tune the thermostat's settings through a Wi-Fi-enabled mobile application, allowing for precise temperature adjustments and system monitoring.

This electrical wiring diagram outlines the setup for connecting single-phase Gazda boilers, suitable for both 2kW and 4kW models. The system is powered through the main circuit breaker, with a 1A circuit breaker placed adjacent to it, designated for the Konlen Wi-Fi thermostat and the circulation pump. Further right, a standard 20A double-pole magnetic contactor is used, capable of handling connections for up to 4kW Gazda boilers. The wiring from the circuit breaker leads to an ammeter, doubling as an electricity consumption meter, which displays current, power, and real-time energy consumption. This phase then moves to the contactor, under the direct control of the Konlen Wi-Fi thermostat. Using a DS18B20 temperature sensor, the Konlen Wi-Fi thermostat regulates the heating medium's temperature by adjusting the electrical phase supplied to the contactor’s coil, with the entire system manageable via Wi-Fi by the user.

This electrical wiring diagram is designed for the installation of single-phase Gazda boilers, suitable for up to 8kW models. The system draws power from the main circuit breaker, beside which a 1A circuit breaker is installed, specifically for the Konlen Wi-Fi thermostat and the circulation pump. To the right of the 1A circuit breaker, a 40A double-pole magnetic contactor is utilized, adequately equipped to connect Gazda boilers of up to 8kW. The electrical phase from this circuit breaker is directed to an ammeter, which also serves as an electricity meter, showcasing current, power, and real-time energy usage. Following this, the phase leads to the contactor, directly controlled by the Konlen Wi-Fi thermostat. The thermostat uses a DS18B20 temperature sensor to monitor and regulate the temperature of the heating medium by appropriately adjusting the electrical phase delivered to the contactor's coil. The entire setup is user-manageable via Wi-Fi, ensuring precise temperature control.

Схема однофазного подключения (eng)
Scheme of electric connection to boilers Galan
This is a simple wiring diagram for single-phase boilers up to 3 kW.
scem for single-phase boiler
For single-phase boilers of 5 and 6 kW. It differs from the previous scheme with another (more powerful, up to 40A) magnetic contactor and another main switch (from 25A to 32A).
Circuit diagram for Geyser 4.5 or 6 or 9 or 15 kW

It is the classical scheme of connection of three-phase electrode boilers. Such as Geyser 9, Geyser 15, and Vulcan 25.

Electrical wiring diagram of the boiler
Electrical wiring diagram of the boiler
Scheme of electric connection to boilers Galan

It is the scheme shows how to connect follow-up a temperature regulator air to the existing control unit with a temperature regulator on water. For an example it is represented Computherm q7, but it is possible to use any air temperature regulator.

Electrical wiring diagram of the boiler

This scheme shows how to connect three phase boiler (for example the Geyser 9 or Geyser 6) to uniphase electric network. It is useful in case you have only 230 V, and the heated area at you is more than 250 m3

Distinctiveness of this scheme is that instead of a one triple-pole automatic breaker we establish three onepolar. Thereby there is an opportunity to operate a boiler three steps of heating.

For example: the Geyser 6 - three levels on 2 kW each level. And the Geyser 9 - three levels on 3 kW each level.

Electrical wiring diagram of the boiler
Electrical wiring diagram of the boiler

This connection diagram for three-phase boilers with ammeter addition.

This connection diagram for three-phase boilers with addition of ammeter and air thermo regulator.

wi-fi connection to basic control of the electrode boiler

In this diagram, we show you how to connect a third-party relay wi-fi to the control box. 

Wiring diagram for 36 kW boiler

This scheme for connecting the boiler Vulcan 36

Electrical connection diagram for Galan 50kW boiler

This scheme for connecting the boiler Vulcan 50