KROS 325 for electrode boilers with power from 6 - 25kW
Universal automatic control electrode boilers Galan
Mains voltage 3ph ~ 380V

Mains voltage, V ~ 380

Frequency Hz 50/60

Own power consumption, no more than 3 W temperature setting range heating medium, +5°C ... 90

Temperature setting range of the second system, 30...70°C

Minimum temperature hysteresis settings, 1.0°C

The range of current limiting regulation, 10A...40A±5%

Power limit control range, 750W...25000W ± 5%

Output tripping current "Cauldron", and 35 Delay setting range of the boiler (after the pump), with 20..120

Maximum temperature of the internal heatsink 70°C

Maximum output power "circulation pump", W200

Maximum power output "Valve" Switched, W1200

The control current in the circuit of external control devices, mA 0,1 Operating mode continuous, uninterrupted Ambient temperature °C -20...+35

The body splash, wall Dimensions (mounting) dimensions mm. 235x200x105 Weight (excluding transducers), 2.3 kg

Solid-state automation for KROS-325 electric boiler (up to 25 kW)

  • Eliminates the inconvenience of starting a system with an electric boiler - soft start
  • Control of two circulation systems (dual circuit heating)
  • Regulation and stabilisation of current consumption
  • Integrated ammeter
  • Integrated time programmer enables efficient adjustment to a dual tariff electricity meter
  • System performance with wide variations in line voltage.
  • Two universal inputs for control
  • Eliminates the main disadvantages of THERMINAL boilers
  • Multilevel safety system
  • Silence
  • 3 years warranty

DOES NOT REQUIRE WATER SUPPLY* for boiler operation.

* The specific conductivity of the coolant is in the range of 350~1200 mS (milliSiemens).

Exceptions are:
1. Distilled water and water approximating softness, resistivity to distilled water. (solution -> add salt or soda).
2. Water with high salt or iron content (solution -> dilute with rain or distilled water).

Destination

The KROS-325 (previously KROS-25) controllers are designed for providing safe automatic operation of three-phase electric heating systems based on electrode and heating element boilers with maintenance of the set heating mode and electricity consumption parameters.

 The KROS-325 controls two systems of heat carrier circulation simultaneously (contains a separate channel temperature sensor and electrovalve/second pump contact control group for hot water system arrangement (in summer without heating the heating system) or floor heating with independent temperature settings in the systems.

The KROS-25 system ensures the safe and efficient operation of electrode boilers in heating systems made of any material and allows for the use of normal water as the heating medium.

Device and principle of operation

 The KROS-325 is a microprocessor-controlled device with solid-state switching of loads (boiler and pump).
 The built-in programmable daily timer with real time clock performs on/off/switching of boilers according to the daily programme set by the user. For example, in order to use the night tariff for electricity, program the electric boiler from 23.00 till 7.00, and during the rest of the day the enabling operation command for the gas (second) boiler will be given.
 The set and current parameters of the system operation are indicated on the display and LEDs.
 Functionally, the KROS-25 consists of five controllers and three boiler power controllers controlled by them, an electronic pump control switch and a three-way valve control relay (or an additional pump).
 The boiler current controller limits and stabilises the current (power) of each phase at a level set by the user with a knob on the front panel. For example, for a 9kW boiler, the maximum current is set at 14A.  Then the current on any electrode of the boiler will not exceed the set value under any circumstances (mains voltage surges, increased conductivity of the coolant, etc.). Regulation ? smooth, with the current value of the boiler current displayed on the digital display.
 The second function of this controller is to protect the system against short-circuits in the load, in the event of which the boiler switches off immediately and then restarts itself after 5 seconds.
The primary system coolant temperature controller (1) shuts down the boiler when the coolant temperature in the heating system reaches the value set by the user. The coolant temperature cannot be higher than the set value even if the external control devices connected to the KROS-15 continue to issue the "Heating" command.
 The Dt1 coolant temperature sensor (Fig.1) is a digital overhead sensor.
 The temperature controller (2) of the additional (second) system controls the boiler and the electro-valve/second pump (switches the hot water flow into the additional (second) system) to reach the temperature of the heating medium in this system set by the user. This controller has priority over the other controllers with respect to the maximum temperature of the heating medium/air.
 The Dt2 coolant temperature sensor (figure 1) is a digital overhead sensor.
 When the temperature reaches the upper limit (set by the user), the temperature controller (2) switches the solenoid valve/stops the second pump for boiler operation to the main (first) system and transfers the priority of the boiler control to the temperature controller (1).
 When the temperature drops to a lower value (set by the user), the controller (2) switches the solenoid valve/second pump back on to operate the second system and turn the boiler on.
 Controller of external control devices allows to control heating system with different types of devices from simple switch to computer ("Smart House"), and the number of control devices connected to KROS-325 at the same time is not limited.
 The controller has two control inputs, for one of which the "heating" command is the closure of its contacts, and for the other - the opening of its contacts (see section 5.2.2. Connecting external control devices).
 The internal temperature controller protects the KROS-325 against overheating of the internal and external (radiator) parts of the appliance to prevent its failure by switching off the boiler and pump power. Once the appliance has cooled down, the controller automatically resumes system operation, retaining the previously set parameters.

 